Direct answer:Candidates are identified in the FDA database based on intended uses and technical characteristics, and the corresponding classification legislation and exemptions are checked. The applicability of the 510(k) exemption can only be judged on the basis that the specific product is consistent with the definition and meets the restrictions.

Write product uses before querying

A sentence in English describes what the product does, for whom, for where. A separate list of working principles, electrical power, human contact, use patterns and major labels is declared. Trade names can be used as search terms, but the same trade names may be used for different purposes and regulatory categories. Information is maintained separately for each model with different uses or technologies.

Identify candidate product codes in FDA’s database

Open FDA Product Classification Database, give priority to searching with a common name or functional keyword in English. If the product code or regulation number is known, it can be found directly by that field. Match the results of a possible match to each other.

  • Device / Regulation Description:The name of the device and classification description of the database entry.
  • Product Code / Regulation Number:Document product codes and corresponding classification code numbers separately.
  • Device Class / Submission Type:Recording the type of device and the type of pre-market declaration indicated in the database.

Query example: manual toothbrush EFW

Use normal manual toothbrushes as an example to search the database. toothbrushOpen toothbrush, manual。EFW entry for FDAList Class I、21 CFR 872.6855 and 510(K) Exempt。 The classification code is then opened to read the definition of the device, and the exemption to which the provision is directed is checked for applicability.

This example demonstrates the query order. Candidate entries should be retraced to the facts of a product that carries electricity, uses other working principles or adds different uses.

The database says "exemption." What else needs to be checked?

The proposed model for sale is confirmed in the definition of equipment in the classification code, and the restrictions set out in the corresponding article are read. For the purposes of this example,21 CFR 872.6855Clear immunity. 21 CFR 872.9Restricted. Emphasis should be placed on actual intended uses versus basic science and technology; The pre-market declaration requirement shall be reassessed when there are differences in use or essential technology, as described in the legislation.

The judgement record may specify the model, use a description version, code, statutory number, exemption limits, item-by-item matching of results and date of reconciliation of information. In the absence of key information, record pending confirmation and retain candidate codes.

How can we narrow down when multiple codes are found?

Priority is given to excluding entries that do not match the intended use or rationale, and to comparing the definitions of population, use environment and classification. Codes cannot be determined on the basis of appearances similar, the same type of items or the vendor’s propaganda. If two entries are still possible, labels, instructions and technical information are collated and further checks are made by the project team; If necessary, the formal classification of the FDA should be followed up.

What else do we do before we go to the market after the waiver is confirmed?

After confirming the pre-market path, pressestablishment registration and product listing guideReconciling the role of the enterprise and its sequencing. If you know which models you want to list, you can check them directly.Denise Listing Serviceand requests for information.

510(k) Exemptions relate to pre-market notifications. Businesses should still verify their registration, product listing, labelling, quality systems, UDI and post-market obligations, as well as each of the possible exceptions, on a product-specific basis and on an operational basis. The establishment registration and product listing records in the database reflect only the corresponding registrations.

Enterprises that have identified product paths and are prepared to check their registration and listing, can be viewed General Service Overview of Media service FDA。

Official sources and review records

What information is available before the assessment is submitted?

Prepare a description of the use in English, a major declaration, a label or description, a model and a working principle. If a candidate code has been found, attach database entries and undefined locations. View Device classification and pathway assessmentor 510(k) Exemption assessment servicesOr maybe.Tell us about your product。