Direct answer:Laser, X-ray, microwave and other equipment likely to emit radiation from electronic products shall be subject to the requirements of the FDA Electronic Production Control (EPRC) by product structure, type of radiation and use; Where applicable, manufacturer registration, product reporting, records, performance standards and import information are checked. If the product is also medical device, the medical device regulation may also apply.
I. Confirmation of whether products are within EPRC
The regulation of products depends on whether they fall within the statutory scope and applicable provisions of the irradiation of electronic products. The initial screening shall collect the power and operating principles, type of launch, wavelength/energy, product use and model group. If there is a medical use or a medical claim, a different medical status should also be determined.
II. Checking product codes and performance standards
Identify product types, definitions and applicable performance standards based on FDA radiation product categories and product code resources. The technical requirements for products such as lasers, diagnostic X-rays, microwaves, sunlight, etc. are different and cannot be treated in an integrated manner based solely on “electronic products”.
III. ACCESS TO REGISTRATION, REPORTING AND RECORDING OBLIGATIONS
Manufacturers should check the reporting and recording requirements of 21 CFR Parts 1000–1005 and 21 CFR 1002 by product category. Some products require product reports, supplementary reports, annual reports or other material. The applicable reports should normally be submitted before the product enters the United States interstate business; FDA proposes to set aside processing time for imported products.
IV. PREPARATION OF THE REPORT AND ACCESSMENT NUMBER
The reporting information usually requires the identification of manufacturers, models, product codes, technical parameters, performance standards and test/quality control information. When the report is received, the FDA assigns accession Number to file management and communication. This number confirms that the report was received and does not demonstrate that the product passed the FDA security clearance.
V. Inspection of imports and labelling
Form FDA 2877, manufacturer information, product model, report number and annual report statement prepared at the time of import in accordance with applicable requirements. FDA checks relevant information on applicable products in import reviews. Certification statements, labels and other technical documents should also be checked on a product-specific basis.
Preparation list of recommendations
- Type of product, use, working principles and type of radiation.
- Technical specifications, test reports, performance standards and manufacturer quality control information.
- Manufacturers are registered and already have FDA product reports/Accession Number.
- Import Scheme, FDA 2877 Application and Customs declaration information.
- Persons responsible for the follow-up year, supplementary reports and record-keeping.
Official sources
- FDA:Getting a Radiation Emitting Product to Market — Frequently Asked Questions
- FDA:Importing Radiation-Emitting Electronic Products
- FDA:Does the Product Emit Radiation?
Date of official data check: 2026-10-27. The product-specific reporting and import obligations are recognized item by product code, standard and model information.
View radiation-emiting project FDA compliance service
Continue reading and preparation
- Which products may be subject to FDA radiation-emitting product requirements?
- Radiation Products Report and Accessation Number
Further consolidation of project information is availableManufacturer registration and product reports; The scope, processing cycles and costs are shown on the corresponding service page.